Opel of Frontera + Cars of mark Opel Frontera + Current leaving and service + The engine + Cooling and heating systems + The power supply system and release + Engine electric equipment + Coupling + Manual box of a gear change + Kardannye shaft, the main transfer + Brake system + Suspension bracket and steering + Body - Onboard electric equipment Diagnostics of malfunctions of an onboard electric equipment Safety locks Fusible inserts (thermal relays) Chain breakers (thermal relays) The relay Lighting devices Removal and installation of a sound signal Servomotor of adjustment of range of light Screen wiper Cleaner of back glass Electric schemes + Controls and operation + Electric equipment schemes |
Diagnostics of malfunctions of an onboard electric equipment
The structure of a typical electric contour can include an electric component, various switches, the relay, electromotors, safety locks, fusible inserts or the breakers of the contour concerning the given component, and also conducting and the electric sockets serving for connection of a component with the battery and weight of a body. For simplification of a problem of search of malfunctions of electric contours in the end of the Management basic schemes of electric connections are enclosed. Before starting works on elimination of malfunctions any of electric contours, attentively study the corresponding scheme as more as possible to be clear in the mind about its functional purpose. Narrowing of a circle of troubleshooting is usually made at the expense of gradual revealing and an exception, normally functioning components of the same contour. At simultaneous failure at once several components or contours most a refusal plausible reason is перегорание a corresponding safety lock or grounding infringement (different contours in many cases can become isolated on one safety lock or the grounding plug). Electric equipment refusals frequently speak the elementary reasons, such as corrosion of plugs, safety lock failure, combustion of a fusible insert or defect of the relay of switching. Make visual check of a condition of all safety locks, conducting and electric sockets of a contour before starting more concrete check of serviceability of its components. In case of application for troubleshooting of diagnostic devices carefully plan according to applied electric schemes in what points of a contour and in what sequence it is necessary to connect the device for the purpose of the most effective revealing of defect. The number of the basic diagnostic devices includes a tester of electric chains or the voltmeter (it can be used also 12 In a control lamp with the complete set of connecting wires), the indicator of a continuity of a piece of a contour (sampler) including a bulb, own power supply and the complete set of connecting wires. Besides always it is necessary to have in the car the complete set of wires for start of the engine from the auxiliary source, equipped with clips of type a crocodile and, it is desirable, the breaker of a contour which can be applied to shunting and connection of various components of an electric equipment in the course of contour diagnostics. As already it was mentioned above before starting check of a chain by means of the diagnostic equipment, define under schemes of a place of its connection. PRESSURE STOCK-TAKING Pressure stock-takings are made in case of infringement of functioning of a contour.
Revealing of absence of pressure testifies to malfunction presence between the given point of a contour and last from checked up earlier (where pressure was present). In most cases a cause of a failure is easing of electric connections and infringement of quality of contacts. The remark Remember that a food on some of contours of an onboard electric equipment moves only in ignition key "АСС" positions (Lay) or "RUN" (Movement). SHORT CIRCUIT SEARCHES One of methods of searches of short circuit is extraction of a safety lock and connection instead of it a lamp-sampler or the voltmeter. Pressure in a contour should be absent.
Similar check can be made for each of contour components, including switches. CHECK OF SERVICEABILITY OF GROUNDING The given check is made for the purpose of definition of reliability of grounding of a component.
CONDUCTIVITY STOCK-TAKINGS Check is made for the purpose of revealing of breakages of an electric chain.
In the similar image it is possible to check up and serviceability of the switch, having connected a sampler to its plugs. While translating the switch in position "Vkl" the control lamp-sampler should light up. BREAKAGE LOCALIZATION At diagnostics of the suspect on presence of breakage of a contour visually to find out a cause of defect it appears difficult enough as survey of plugs on presence of corrosion or infringement of quality of their contacts is complicated in a kind of limitation of access to them (usually plugs are closed by the socket case). Sharp twitchings of the case of a socket on the gauge or a plait of its wires in many cases leads to conductivity restoration. Do not forget about it at attempts of localisation of a cause of a failure of the suspect on contour breakage. Astably arising refusals can have the reason oxidation of plugs or infringement of quality of contacts. Diagnostics of malfunctions of electric chains at all does not represent a stubborn problem under condition of accurate representation that the current arrives to all electric loadings (a lamp, the electromotor, etc.) from the battery on wires through switches, the relay, safety locks, fusible inserts, and then comes back in the battery through weight of the car. Any problems connected with refusal of an electric equipment can have the reason only stopping delivery on them of an electric current from the battery or its return to it. |
|