Subaru Legacy/Outback

1999-2003 of release

Repair and car operation



Subaru Legasi, Autbek
+ Cars Subaru Legacy, Outback
+ The operation manual
+ Routine maintenance
+ The engine
+ Systems of cooling, heating
+ The power supply system and release
+ Engine electric equipment
+ Manual box and differential
+ Automatic transmission
+ Coupling
+ Brake system
+ Suspension bracket and steering
+ Body
- Onboard electric equipment
   Specifications
   Search of causes of failures of an electric equipment
   Safety locks - the general information
   Chain breakers - the general information
   The relay - the general information and check of serviceability of functioning
   Details of a lining of onboard electroconducting
   System of additional safety (SRS) - the device and a functioning principle
   Diagnostics of malfunctions SRS
   Removal and installation of components SRS
   Control system of speed (темпостат) - the device and a functioning principle
   Check of serviceability of functioning of components and problem diagnostics темпостата
   Removal, check of a condition and installation of components of a control system by speed
   Combination of devices - the general information and a principle of functioning of components
   Problem diagnostics of components of a combination of devices
   Removal, service and installation of a combination of devices, check of a condition of components
   Heating of back glass and rear-view mirrors - the general information, check of serviceability of functioning of components, regenerative repair of a thermoelectric heating element
   Heating of brushes of screen wipers - the general information, check of serviceability of functioning of components, regenerative repair of a thermoelectric heating element
   Removal, check of a condition and installation of switches of management by functioning of the electric drive of regulators Glass lifts
   The electric drive of rear-view mirrors - check of serviceability of functioning
   Removal check and installation of the switch of management by functioning of the electric drive of external rear-view mirrors
   Removal, check of a condition and installation of the switch of management by functioning of the electric drive of the top hatch
   Removal, check of a condition and installation combined подрулевых switches
   Check of serviceability of functioning of electromotors of a drive of screen wipers, removal, check and installation of the operating relay of a back screen wiper on models Legacy of Universal/Outback
   Check of the relay and switches of lighting and alarm devices
   Removal and installation of lighting devices, replacement of lamps
   Removal, check of a condition and installation of small horns and the horn switch
   Check of a condition and replacement of contact group of the switch of ignition
   The uniform lock - the device, a functioning principle, diagnostics of malfunctions
   Removal, check of a condition and installation of components of the uniform lock
   System иммобилизации the engine - the device, a functioning principle, diagnostics of malfunctions
   Removal and installation of components of system иммобилизации the engine
   Removal and installation of assemblage of a radio receiver
   Removal and installation of loudspeakers
   Check of a condition and regenerative repair of the window aerial of a radio receiver
   Removal, installation and check of a condition of the antenna amplifier of a radio receiver
   Removal and installation прикуривателя
   + Schemes of electric connections


8eee0de7



The uniform lock - the device, a functioning principle, diagnostics of malfunctions

The scheme of an arrangement of the basic operating components of the uniform lock

1 — the Module of management of the uniform lock
2 — the Switch of a latch of a door of a back (model Legacy of Universal/Outback)

3 — Switches of door-locks


The basic scheme of the uniform lock

1 — the management Module
2 — the Target signal of blocking of the lock
3 — the Target signal of unlocking of the lock
4 — the door-lock Switch
5 — the Activator of the lock of a driver's door
6 — the Activator of the lock of the right forward door

7 — the Activator of the lock of the left back door
8 — the Activator of the lock of the right back door
9 — the Activator of the lock of a door of a back
10 — Weight
11 — the Battery


 Models of cars considered in the present Management are equipped by system of additional safety (SRS). Before to start performance of any works near to the block of a pillow of safety, a steering column or the instrument panel, disconnect SRS in order to avoid reception of traumas at its casual operation (the Section System of additional safety (SRS) - the device and a functioning principle see)! Electroconducting of chain SRS is easy for distinguishing on yellow colour of isolation.


The general information

The number of components of the uniform lock includes the management module, assemblage of the switch/activator of a driver's door, and also activators of locks of passenger doors and a back door (model Legacy of Universal/Outback).

Blocking/unlocking of a driver's door by means of the internal switch of the lock leads to blocking/unlocking of all other doors of the car. The basic scheme of the uniform lock is presented on an illustration.

As a subsystem the structure of the uniform lock includes the remote control system which basic components are the module of management of the uniform lock, built in a head of a key a remote control (transmitter), door switches, and also lamps of the alarm system and салонных fixtures.

Panel DU functions on a radio frequency that allows to use the transmitter from any directions.

Diagnostics of malfunctions

Diagnostic card of refusals


Serviceability of functioning of locks of forward doors is broken at unlocking/lock-out by their key

 PERFORMANCE ORDER

1. Check up serviceability of a condition of the cylinder of a door-lock.
2. Make sure that there was no detachment or jamming приводной draughts of the activator.


Serviceability of functioning of a control system of the uniform lock is broken

 PERFORMANCE ORDER

1. Check up serviceability of a condition of a corresponding safety lock (see more low).
2. Check up serviceability of a condition of contours of giving of a food and grounding of the module of management of the uniform lock (see more low).
3. Check up serviceability of a condition of contours of switches of door-locks (see more low)
4. Check up serviceability of a condition of activators of door-locks (see more low).


Serviceability of operation of the switch of the lock of a concrete door is broken

 PERFORMANCE ORDER

1. Check up serviceability of a condition of a contour of the switch (see more low)
2. Make sure of reliability of connection приводной draughts of the activator of the lock of a corresponding door.


Serviceability of operation of the activator of the lock of a concrete door is broken

 PERFORMANCE ORDER

1. Check up serviceability of a condition of a contour of the activator (see more low)
2. Make sure of reliability of connection приводной draughts of the activator.


Serviceability of functioning of system of remote control (ДУ) is broken by the uniform lock

 PERFORMANCE ORDER

1. Check up a condition of an element of a food of the transmitter (see more low).
2. Check up serviceability of a condition of a safety lock (see more low).
3. Check up serviceability of a condition of contours of giving of a food and grounding of the module of management of remote control (see more low).
4. Replace the management module (see Has undressed Removal, check of a condition and installation of components of the uniform lock).


Refusal of registration of the transmitter takes place

 PERFORMANCE ORDER

1. Check up a condition of an element of a food of the transmitter (see more low).
2. Check up serviceability of a condition of a contour of a registration socket (see more low).


Serviceability of operation of a door-lock on command from panel DU is broken

 PERFORMANCE ORDER

1. Check up a condition of an element of a food of the transmitter (see more low).
2. Check up serviceability of a condition of the alarm switch of a key (see more low).
3. Check up a condition of the door switch (see more low).
4. Replace the management module (see Has undressed Removal, check of a condition and installation of components of the uniform lock).


Serviceability of functioning of lamps of the alarm system is broken at giving of commands from panel DU

 PERFORMANCE ORDER

1. Check up a condition of an element of a food of the transmitter (see more low).
2. Check up serviceability of a condition of the alarm switch of a key (see more low).
3. Check up serviceability of functioning of the alarm system (see more low).
4. Replace the management module (see Has undressed Removal, check of a condition and installation of components of the uniform lock).


Serviceability of functioning of lamps of illumination of salon and illumination of the switch of ignition at giving of commands from panel DU is broken

 PERFORMANCE ORDER

1. Check up a condition of an element of a food of the transmitter (see more low).
2. Check up serviceability of a condition of the alarm switch of a key (see more low).
3. Check up serviceability of a condition corresponding салонных fixtures (see Has undressed Removal and installation of lighting devices, replacement of lamps).
4. Check up a condition of the door switch (see more low).
5. Replace the management module (see Has undressed Removal, check of a condition and installation of components of the uniform lock).


Checks

 Schemes of electric connections of corresponding components are presented in the end of Rukovdstva.


Check of safety locks

Take safety locks № 2 (15), SBF-6 (30) (the main assembly block) and № 3 (15) (the assembly block of safety locks and the relay). Visually estimate a condition of the safety locks, fused elements replace. If safety locks in norm, check up serviceability of a condition of contours of giving of a food and grounding of the module of management of the uniform lock/system of remote control (see more low).

Check of serviceability of a condition of contours of giving of a food and grounding of the module of management of the uniform lock

 PERFORMANCE ORDER

1. Disconnect electroconducting from the management module (see Has undressed Removal, check of a condition and installation of components of the uniform lock).
2. Measure pressure between plugs №№ 5 (+) and 16 (+) socket В176 of a plait of electroconducting and weight of the chassis. If result of measurement structure ляет more than 10 In, pass to a following stage of check, otherwise check up on presence of breakages and short circuit electroconducting on a chain site between the module of management and a safety lock.
3. Measure resistance between plugs №№ 6 (+) and 14 (+) socket В176 and weight of the chassis. If the result of measurement makes less than 10 Ohm, chains of giving of a food and grounding are perfectly in order, otherwise repair electroconducting.


Check of serviceability of a condition of contours of switches of door-locks

 PERFORMANCE ORDER

1. Disconnect electroconducting from the module of management of system of the uniform lock (see Has undressed Removal, check of a condition and installation of components of the uniform lock).
2. Measure resistance between the plug № 7 (+) socket В176 and weight of the chassis in position "is unblocked" of the switch. If the result of measurement makes more than 10 Ohm, the following stage of check can be lowered.
3. Repeat the previous check in position "is blocked" of the switch. If the result of measurement makes less than 10 Ohm, pass to a following stage of check, otherwise the switch in norm.
4. Disunite a contact socket of electroconducting of the switch/activator of a door-lock (see Has undressed Removal, check of a condition and installation of components of the uniform lock) and measure resistance between plugs № 1 and № 3 in position "is unblocked" of the switch. If the result of measurement makes less than 10 Ohm, pass to the check final stage, otherwise replace switch/activator assemblage (see Has undressed Removal, check of a condition and installation of components of the uniform lock).
5. Repeat the previous check in position "is blocked" of the switch. If the result of measurement makes less than 10 МОм, replace switch/activator assemblage (see Has undressed Removal, check of a condition and installation of components of the uniform lock), otherwise check up on presence of signs of breakage and short circuit electroconducting on a chain site between the module of management and the corresponding switch.


Check of serviceability of a condition of a contour of activators of door-locks

 PERFORMANCE ORDER

1. Measure pressure between plugs №№ 17 (+) and 18 (+) socket В176 and weight of the chassis. If the result of measurement makes more than 10 In, pass to a following stage of check, otherwise replace the module of management of the uniform lock.
2. Check up a condition of the corresponding activator (see Has undressed Removal, check of a condition and installation of components of the uniform lock), in case of need make its replacement. If the activator is perfectly in order, check up on presence of signs of breakage and short circuit electroconducting on a chain site between the module of management and the activator. Make necessary regenerative repair.


Check of serviceability of a condition of an element of a food of the transmitter of system DU

 PERFORMANCE ORDER

Take from the transmitter of an element of a food and check up its pressure (see Has undressed Removal, check of a condition and installation of components of the uniform lock). If the result of measurement makes more than 2 In, the transmitter as it should be and should be passed to the next check (see above a card of refusals).


Check of serviceability of a condition of a contour of a registration socket of transmitter DU

 PERFORMANCE ORDER

1. Include ignition and disunite a registration socket (see Has undressed Removal, check of a condition and installation of components of the uniform lock). Measure pressure between the plug № 2 (+) socket В176 and weight of the chassis. If the result of measurement makes more than 10 In, pass to a following stage of check, otherwise repair electroconducting / a contact socket.
2. Repeat the above described check at the connected registration socket. If the result of measurement makes 0 In, the registration socket is perfectly in order, otherwise repair electroconducting / a contact socket.


Check of a condition of the door switch

 PERFORMANCE ORDER

1. Measure pressure between plugs №№ 3 (+) and 4 (+) socket В176 and weight of the chassis. If in public the result of measurement differs from value 0 In, the following stage of check can be lowered.
2. Close all doors and repeat the previous check If in public the result of measurement makes nearby 10 In, hence, switch as it should be, otherwise pass to a following stage of check.
3. Disconnect from the door switch electroconducting and measure resistance between plugs № 1 and № 3 (lateral doors) / № 2 (a back door) the switch. If at wrung out to the pressed button of the switch the result of measurement makes more than 10 МОм, pass to the check final stage, otherwise replace the switch.
4. Repeat the above described check at the released switch. If the result of measurement makes less than 1 Ohm, check up on presence of signs of breakage and short circuit electroconducting on a chain site between the module of management and the switch, otherwise replace the switch.


Check of a condition of the alarm switch of a key

 PERFORMANCE ORDER

1. Take from the main assembly block a safety lock № 6 (15) and visually estimate its condition. Fused safety lock replace. If a safety lock in norm, pass to a following stage of check.
2. Take a key from the lock of ignition and measure pressure between the plug № 1 (+) socket В176 and weight of the chassis. If the result of measurement makes 0 In, hence, alarm switch in norm, otherwise pass to a following stage of check.
3. Disconnect from the alarm switch electroconducting. Insert a key into the ignition lock (in position LOCK) and measure resistance between plugs № 1 and № 2 switches. If the result of measurement makes less than 1 Ohm, pass to the check final stage, otherwise replace the alarm switch.
4. Take a key from the lock of ignition and repeat the previous check. If the result of measurement makes less than 1 МОм, replace the alarm switch, otherwise check up on presence of signs of breakage and short circuit electroconducting on chain sites between the switch and a safety lock and between the switch and the management module.


Check of serviceability of functioning of lamps of the alarm system

 PERFORMANCE ORDER

1. Make sure of serviceability of activation of lamps of the alarm system from the corresponding switch on the panel of devices of the car. If lamps blink regularly, pass to a following stage of check, otherwise check up a condition of corresponding electroconducting, make necessary corrections.
2. Take a key from the ignition lock, close all doors (including a back door) and measure pressure between plugs №№ 12 both 13 sockets В176 and weight of the chassis. If the result of measurement makes less than 10 In, replace the module of management of the uniform lock (see Has undressed Removal, check of a condition and installation of components of the uniform lock), otherwise check up on presence of signs of breakage and short circuit electroconducting on a chain site between the module of management and alarm system lamps.



Check of serviceability of functioning of lamps салонных fixtures

 PERFORMANCE ORDER

1. Make sure of serviceability of activation of fixtures from the corresponding switch. If fixtures function regularly, pass to a following stage of check, otherwise check up a condition of corresponding electroconducting, make necessary corrections.
2. Disconnect electroconducting from the module of management of the uniform lock and салонного the fixture. Measure resistance between the plug № 11 sockets В176 and the plug № 2 sockets R52. If the result of measurement makes less than 10 In, hence, chain of the fixture is serviceable, otherwise check up on presence of signs of breakage and short circuit electroconducting on a chain site between the module of management and the fixture.


Check of serviceability of functioning of illumination of the switch of ignition

 PERFORMANCE ORDER

1. Disunite a contact socket of electroconducting of a chain of illumination of the switch of ignition and measure pressure between the plug № 2 (+) socket В224 and weight of the chassis. If the result of measurement makes more than 10 In, pass to a following stage of check, otherwise check up on presence of signs of breakage and short circuit electroconducting on a chain site between the switch of ignition and a safety lock.
2. Disconnect electroconducting from the module of management of the uniform lock. Measure resistance between the plug № 11 sockets В176 and the plug № 1 socket В224. If the result of measurement makes less than 10 In, check up serviceability of a condition of the block of illumination (in case of need make replacement), otherwise repair electroconducting.