Subaru Legacy/Outback

1999-2003 of release

Repair and car operation



Subaru Legasi, Autbek
+ Cars Subaru Legacy, Outback
+ The operation manual
+ Routine maintenance
+ The engine
+ Systems of cooling, heating
+ The power supply system and release
+ Engine electric equipment
+ Manual box and differential
+ Automatic transmission
+ Coupling
+ Brake system
+ Suspension bracket and steering
+ Body
- Onboard electric equipment
   Specifications
   Search of causes of failures of an electric equipment
   Safety locks - the general information
   Chain breakers - the general information
   The relay - the general information and check of serviceability of functioning
   Details of a lining of onboard electroconducting
   System of additional safety (SRS) - the device and a functioning principle
   Diagnostics of malfunctions SRS
   Removal and installation of components SRS
   Control system of speed (темпостат) - the device and a functioning principle
   Check of serviceability of functioning of components and problem diagnostics темпостата
   Removal, check of a condition and installation of components of a control system by speed
   Combination of devices - the general information and a principle of functioning of components
   Problem diagnostics of components of a combination of devices
   Removal, service and installation of a combination of devices, check of a condition of components
   Heating of back glass and rear-view mirrors - the general information, check of serviceability of functioning of components, regenerative repair of a thermoelectric heating element
   Heating of brushes of screen wipers - the general information, check of serviceability of functioning of components, regenerative repair of a thermoelectric heating element
   Removal, check of a condition and installation of switches of management by functioning of the electric drive of regulators Glass lifts
   The electric drive of rear-view mirrors - check of serviceability of functioning
   Removal check and installation of the switch of management by functioning of the electric drive of external rear-view mirrors
   Removal, check of a condition and installation of the switch of management by functioning of the electric drive of the top hatch
   Removal, check of a condition and installation combined подрулевых switches
   Check of serviceability of functioning of electromotors of a drive of screen wipers, removal, check and installation of the operating relay of a back screen wiper on models Legacy of Universal/Outback
   Check of the relay and switches of lighting and alarm devices
   Removal and installation of lighting devices, replacement of lamps
   Removal, check of a condition and installation of small horns and the horn switch
   Check of a condition and replacement of contact group of the switch of ignition
   The uniform lock - the device, a functioning principle, diagnostics of malfunctions
   Removal, check of a condition and installation of components of the uniform lock
   System иммобилизации the engine - the device, a functioning principle, diagnostics of malfunctions
   Removal and installation of components of system иммобилизации the engine
   Removal and installation of assemblage of a radio receiver
   Removal and installation of loudspeakers
   Check of a condition and regenerative repair of the window aerial of a radio receiver
   Removal, installation and check of a condition of the antenna amplifier of a radio receiver
   Removal and installation прикуривателя
   + Schemes of electric connections


8eee0de7



Search of causes of failures of an electric equipment

 Described below procedure allow to make the general diagnostics of a condition of the main electric contours, electronic modules of management however should not be applied to check of electric systems open to injury, in particular, including in the structure!


The general data

The typical electric contour consists of the electric power consumer (a working element), a set of switches, the relay, executive electromotors, safety locks, the fusible inserts/breakers of the chain concerning work of the given element, and also connecting electroconducting, its contact plugs and sockets. For the purpose of simplification of performance of diagnostic procedures in last Section of the present Chapter schemes of electric connections of systems of an onboard electric equipment are resulted.

Before to start search of causes of a failure of the failed consumer of the electric power, attentively study the corresponding electric scheme, try as it is possible to imagine more clearly a principle of functioning of the elements which are a part of the suspected contour. The list of possible causes of a failure can be shown to a minimum by an exception of it of regularly functioning components concerning work of the checked contour. At simultaneous infringement of functioning at once several components, most a refusal plausible reason is failure of the general for corresponding chains of a safety lock / a fusible insert, or grounding infringement.

More often electric equipment refusals speak the elementary reasons, such as oxidation, or fastening easing клеммных connections, failure of a safety lock or a fusible insert, relay refusal, etc. Before to start search of internal defects of actually refused component, attentively check up a condition of all safety locks concerning its functioning, sockets and connecting wires (see Section of the Detail of a lining of onboard electroconducting).

For definition of the list of knots subject to check and contact sockets, study corresponding schemes of electric connections.

To number of the diagnostic equipment more often used by search of refusals of an electric equipment, it is necessary to carry a universal measuring instrument of a chain/voltmeter (for some checks 12-voltnaja the lamp with the complete set of connecting wires also will approach), a lamp-sampler with the individual power supply (sometimes named also a conductivity measuring instrument), an ohmmeter, the power supply with the complete set of connecting wires, and also a set of the wires-crosspieces, equipped various type connecting plugs and, - it is desirable, - the built in breaker of a chain or a safety lock (for shunting of suspicious sites of a chain or electric components). Before to resort to use of the diagnostic equipment attentively study the scheme of electric connections of components of a corresponding contour (Schemes of electric connections see).

At revealing of the reason of refusal having astable character (infringements such usually appear connected with oxidation of contact plugs, or fastening easing клеммных electroconducting connections) the elementary check of a chain which are carried out by twitching of various sites of electroconducting of the corresponding contour in which result the defective piece of a chain is localised can be made. The given check can be made together with any of listed more low in corresponding subsections.

Except the problems connected with infringement of quality of electric connections, it is necessary to carry breakages and short circuits to number of the most probable and often occurring refusals of electric contours in a chain.

Chain breakage is usually caused by mechanical damage токопроводных veins or a detachment of contact plugs that leads to disconnection of an electric contour and the circulation termination in it of an electric current. As a result of chain breakage its working component ceases to function, however corresponding safety locks / fusible inserts do not fail.

As short circuit is called unforeseen a design of a chain short circuit of its electroconducting. Thus the current starts to circulate on the shortest way, in most cases leaving on weight. Short circuits appear connected with infringement of integrity of isolation of electroconducting more often and without fail lead to failure of corresponding safety locks / fusible inserts.

Pressure stock-taking in a chain

Pressure stock-taking is included into number of standard checks in default any consumer of the electric power. Connect one of wires («-») a chain/voltmeter measuring instrument to the negative plug of the battery, or any of reliably earthed points on the car chassis/engine. The second wire of the device connect to клеммному to connection of a checked contour, it is preferable to the nearest to the battery or a safety lock. Submit a food to a contour. Do not forget that some chains запитываются only in certain positions of the switch of ignition. If pressure takes place (the measuring instrument lamp joins, or on the voltmeter indicator the corresponding indication is fixed), the chain piece between checked клеммным connection and the battery means is serviceable.

Continue check in the same spirit, serially passing from one клеммного chain connections to another, moving to a direction from the battery/safety lock. The faulty site of a contour will settle down between a point on which the device will not register presence of pressure and the nearest tested serviceable клеммным connection. More often electroconducting breakage, or oxidation/easing of fastening of a contact element appears a cause of a failure.

Search of the reasons of short circuit

First of all disconnect the consumer () the electric power of a checked contour (electric power consumers, or useful loading of a contour, components for which functioning the current circulating in a chain, such as lamps, electromotors, heating elements, etc. is spent are called) . Take the safety lock protecting the checked contour, and connect to its adjusting plugs a lamp-sampler or the voltmeter. Submit power supplies to a contour, - remember that some of contours запитываются only in certain positions of the switch of ignition. If pressure on safety lock plugs takes place, hence, in a chain there was a short circuit, - pull electroconducting as short circuit can be caused destruction of its isolation and have astable character. If pressure is absent, however the safety lock after replacement continues to fuse at food giving in a chain, means, internal defect of the consumer (it) the electric power, the switch or electroconducting isolation takes place.

Alternatively check can be made by means of an ohmmeter: disunite all contact sockets of a suspected site of a chain and, start to connect an ohmmeter between each of sockets and weight, registration by a measuring instrument of presence of conductivity (the zero indication) testifies to short circuit on weight of the electroconducting connected to corresponding plug of the checked socket.

Search of infringements of grounding

The negative plug of the battery is earthed on "weight" in which quality metal of the power unit, the chassis and bodywork car elements acts. Electric contours большей electric equipment parts are constructed in such a manner that electroconducting is used only for food giving to the consumer from the positive plug of the battery, return of a current to the battery is carried out on weight metal. Told means that fixing elements of consumers of the electric power form themselves a returnable part of an electric chain. In view of the described situation, easing of fastening or corrosion of basic elements of a working component of a chain involves infringement of serviceability of functioning of a contour (from a full exit of the last out of operation before partial refusal of various sites of a chain). In particular, as a result of fixture easing brightness of a luminescence of lighting devices (in particular in the presence of the general grounding with other contour), or speed of rotation of the electromotor (for example, a drive of screen wipers or the fan of system of cooling) can decrease. Thus refusal of one contour can cause infringement of functioning of the another which at first sight in any way have been not connected with failed. Pay attention that on many cars certain knots are connected among themselves by special tyres of grounding. Such tyres are used when there is no direct contact of metal parts of blocks in view of the equipment of support flexible rubber plugs (as, for example, in support of a suspension bracket of the power unit).

For check of serviceability of grounding of a component disconnect the battery and connect one of ohmmeter wires to the obviously reliably earthed point of the car. The second wire of a measuring instrument connect to a point of grounding of a checked component. The device should fix zero resistance, otherwise it is necessary to check up serviceability of electric connection (see further).

In the presence of suspicions on quality infringement клеммного connections, disassemble contact knot of grounding and smooth out to pure metal interfaced surfaces of plugs. Try to remove completely all traces of corrosion and a dirt, then scratch out a knife a paint, achieving unequivocal contact of metal surfaces. At knot assemblage take care of durability of a tightening of fixture. Between plugs of electroconducting and contacts of weight for the quality assurance of electric connection lay washers with a notch. In order to avoid corrosion development in the future cover joined клеммные connections бескислотным with vaseline or silicone greasing. Good means are also an aerosol for hermetic sealing of components of system of ignition and water-repellent greasing.

Search of breakages of a chain

Astable refusals of consumers of the electric power appear connected with quality infringement клеммных connections at the expense of oxidation or fixture easing more often. Often for component reduction in a working condition, it appears to pull simply enough a corresponding plait of electroconducting / an electric socket. The most simple way of search of breakage of a chain is check of its working sites on conductivity presence. Disconnect power supplies of a contour and take advantage of the equipped independent power supply a measuring instrument. Connect measuring instrument wires to both exits of a checked chain (the plug of giving of a food and well earthed point). If the device fixes conductivity presence (zero resistance/operation of a lamp-sampler), hence, the checked site of a chain is serviceable. Breakage otherwise takes place. In the similar way serviceability of functioning of switches can be checked up.

Electric sockets - the general data

The majority of contact sockets of chains of an onboard electric equipment are made of plastic and are multicontact. Reliability of a joint of half of such sockets is provided защелкиванием lock uvulas of the clamps built in in tips. Large sockets, such as some of the devices of the car located under the panel, are fastened passed through the central part of tips by through bolts more often.

For рассоединения the sockets equipped with plastic clamps the small screw-driver to which should wring out accurately lock uvulas (preliminary attentively usually is used study a design of the joined socket - often to measure a way of fixing of its half by eye completely not simply; some sockets are equipped by several lock knots). Pull only for the tip, and at all for an electroconducting plait, in order to avoid casual damage of the contact plugs built in in a socket.

Sockets always consist of two sections plugs of one of which enter in plugs another. At studying of the schematic image of a socket try to define first of all which of its sections it is presented on an illustration, - connected to a plait, or fixed on a component. Remember that plugs of one section of a socket always are placed mirror in relation to plugs another.

At conductivity stock-taking between plugs of a socket or pressure measurement between any of plugs and "weight" always connect probeы a measuring instrument to plugs from the back (cordlike) party of corresponding section of a socket.

 In case of need use probeы a tiny design, or enter into a socket the unbent writing paper clip to which then it is possible to connect a wire of a measuring instrument by means of a clip of type "crocodile".


If the socket has a tight design, the measuring instrument can be connected with клеммной the socket parties, however, in such situation it is necessary to observe extra care in order to avoid damage of plugs.